Conventional structural fire design is primarily based on standard fire curves that assume uniform heating throughout a compartment. However, observations from large open-plan compartments have shown that real fires often develop as travelling fires, producing highly non-uniform thermal environments that move across a compartment over time. Such fire behaviour can significantly influence the thermal and structural response of steel structures and may lead to failure mechanisms that differ substantially from those predicted using conventional design fires. Despite increasing recognition of travelling fires in performance-based fire engineering, the response of structural elements and structural systems subjected to travelling fire exposure remains insufficiently understood.

This research investigates the behaviour of structural elements and assemblies under travelling fire scenarios through finite element modelling. The numerical models were developed in Abaqus to simulate the thermal and thermo-mechanical response of steel columns, restrained steel beams, and steel frame structures exposed to travelling fires. The numerical models were validated against a range of experimental fire tests. Following this, a systematic analysis of column, beam, and multistorey frames is performed under real travelling fire exposure and compared with standard, parametric, and analytical travelling fire cases.

Initially, the behaviour of steel columns was investigated under three travelling fire scenarios and compared with the ISO 834 standard fire. The results showed that travelling fires produce non-uniform temperature distributions that significantly change the failure location, deformation characteristics, and instability mechanisms. In addition, higher load ratio and eccentricity reduced critical temperature and accelerated instability. Travelling fire scenarios generally resulted in higher critical temperatures than the ISO fire, due to the retention of stiffness in the cooler regions of the column. Furthermore, when the response was investigated using actual degree of utilisation, the differences between concentric and eccentric loading conditions became less pronounced, demonstrating the importance of considering member utilisation when assessing fire resistance.

The response of restrained steel beams subjected to travelling fires was also examined and compared with equivalent parametric fires, the Improved Travelling Fire Methodology (iTFM), and the ISO fire curve. The results demonstrated that no single fire scenario is universally critical. Travelling fires produced gradual heating, delayed deformation, and partial recovery during cooling, whereas ISO and parametric fires generated rapid stiffness degradation and earlier failure. Among the travelling fire scenarios, TF2 produced the most severe combined force-deformation response, while TF3 generated the largest beam deflections due to prolongedheating associated with ventilation-controlled conditions. The iTFM model captured the general travelling fire behaviour reasonably well but tended to provide conservative predictions of temperature, force development, and structural deformation.

To investigate the overall structural behaviour, both a single-storey steel frame and a five-storey steel frame were analysed under travelling fires, equivalent parametric fires, and iTFM fire exposure. The results demonstrated that structural response is strongly governed by non-uniform thermal distributions, fire-induced load redistribution, and progressive stiffness degradation. Under travelling fire exposure, a significant portion of the applied load was redistributed from heated columns to adjacent members due to stiffness loss. In several cases, columns located outside the directly heated region became more critical than the heated columns due to increased effective degree of utilisation. The analysis further showed that the behaviour of the beams was controlled by column failure rather than by individual beam failure. The assumption of Uniform-temperature generally produced conservative predictions, while actual travelling fires often led to less severe responses because cooler regions offer continued structural resistance.

The findings from this research reveal that travelling fires produce structural responses that differ from those predicted using conventional design fire approaches. The outcomes of this study recommend that structural design should consider envelope responses from multiple fire scenarios rather than relying on a single fire case for safe, sustainable and resilient structures.

Date of AwardOct 2026
Original languageEnglish
SupervisorNaveed Alam (Supervisor) & Ali Nadjai (Supervisor)

Keywords

  • structural fire engineering
  • travelling fires
  • steel structures
  • thermal-mechanical response
  • fire resistance
  • structural stability
  • non-uniform heating
  • load redistribution
  • progressive collapse