The effect of patient gait on the material properties of UHMWPEin hip replacements

S Davey, JF Orr, FJ Buchanan, JR Nixon, D Bennett

Research output: Contribution to journalArticle

Abstract

The wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular components in total hip replacements (THRs) hasbeen shown to be highly dependent on the direction of shear. Greatly reduced wear rates have been reported for unidirectional,compared to multidirectional, articulation in vitro. This work for the first time enables investigation of a relationship betweenclinical wear conditions, as determined by patient gait path, and the mechanical and structural changes that occur within theUHMWPE acetabular component. Individual patients’ wear paths were determined prior to revision operation from hip jointkinematics measured by clinical gait analysis. The material properties of the acetabular components removed during the revisionoperation were subsequently analysed. A technique using Fourier transform infra- red analysis (FTIR) was developed to quantifythe orientation of the individual UHMWPE lamellae. This study shows that there is a direct relationship between a patient’s clinicalgait path and the molecular properties of their UHMWPE acetabular socket. Patient kinematics are an important factor affectingthe wear and long-term biocompatibility of UHMWPE used as a bearing surface in THR.r 2005 Elsevier Ltd. All rights reserved.
LanguageEnglish
Pages4993-5001
JournalBiomaterials
Volume26
Publication statusPublished - 1 Mar 2005

Fingerprint

Gait
Hip
Hip Replacement Arthroplasties
Fourier Analysis
Biomechanical Phenomena
ultra-high molecular weight polyethylene

Cite this

Davey, S., Orr, JF., Buchanan, FJ., Nixon, JR., & Bennett, D. (2005). The effect of patient gait on the material properties of UHMWPEin hip replacements. Biomaterials, 26, 4993-5001.
Davey, S ; Orr, JF ; Buchanan, FJ ; Nixon, JR ; Bennett, D. / The effect of patient gait on the material properties of UHMWPEin hip replacements. In: Biomaterials. 2005 ; Vol. 26. pp. 4993-5001.
@article{b60ac2bb66c143d09af2608921dd680a,
title = "The effect of patient gait on the material properties of UHMWPEin hip replacements",
abstract = "The wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular components in total hip replacements (THRs) hasbeen shown to be highly dependent on the direction of shear. Greatly reduced wear rates have been reported for unidirectional,compared to multidirectional, articulation in vitro. This work for the first time enables investigation of a relationship betweenclinical wear conditions, as determined by patient gait path, and the mechanical and structural changes that occur within theUHMWPE acetabular component. Individual patients’ wear paths were determined prior to revision operation from hip jointkinematics measured by clinical gait analysis. The material properties of the acetabular components removed during the revisionoperation were subsequently analysed. A technique using Fourier transform infra- red analysis (FTIR) was developed to quantifythe orientation of the individual UHMWPE lamellae. This study shows that there is a direct relationship between a patient’s clinicalgait path and the molecular properties of their UHMWPE acetabular socket. Patient kinematics are an important factor affectingthe wear and long-term biocompatibility of UHMWPE used as a bearing surface in THR.r 2005 Elsevier Ltd. All rights reserved.",
author = "S Davey and JF Orr and FJ Buchanan and JR Nixon and D Bennett",
year = "2005",
month = "3",
day = "1",
language = "English",
volume = "26",
pages = "4993--5001",
journal = "Biomaterials",
issn = "0142-9612",
publisher = "Elsevier",

}

Davey, S, Orr, JF, Buchanan, FJ, Nixon, JR & Bennett, D 2005, 'The effect of patient gait on the material properties of UHMWPEin hip replacements', Biomaterials, vol. 26, pp. 4993-5001.

The effect of patient gait on the material properties of UHMWPEin hip replacements. / Davey, S; Orr, JF; Buchanan, FJ; Nixon, JR; Bennett, D.

In: Biomaterials, Vol. 26, 01.03.2005, p. 4993-5001.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The effect of patient gait on the material properties of UHMWPEin hip replacements

AU - Davey, S

AU - Orr, JF

AU - Buchanan, FJ

AU - Nixon, JR

AU - Bennett, D

PY - 2005/3/1

Y1 - 2005/3/1

N2 - The wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular components in total hip replacements (THRs) hasbeen shown to be highly dependent on the direction of shear. Greatly reduced wear rates have been reported for unidirectional,compared to multidirectional, articulation in vitro. This work for the first time enables investigation of a relationship betweenclinical wear conditions, as determined by patient gait path, and the mechanical and structural changes that occur within theUHMWPE acetabular component. Individual patients’ wear paths were determined prior to revision operation from hip jointkinematics measured by clinical gait analysis. The material properties of the acetabular components removed during the revisionoperation were subsequently analysed. A technique using Fourier transform infra- red analysis (FTIR) was developed to quantifythe orientation of the individual UHMWPE lamellae. This study shows that there is a direct relationship between a patient’s clinicalgait path and the molecular properties of their UHMWPE acetabular socket. Patient kinematics are an important factor affectingthe wear and long-term biocompatibility of UHMWPE used as a bearing surface in THR.r 2005 Elsevier Ltd. All rights reserved.

AB - The wear of ultra-high molecular weight polyethylene (UHMWPE) acetabular components in total hip replacements (THRs) hasbeen shown to be highly dependent on the direction of shear. Greatly reduced wear rates have been reported for unidirectional,compared to multidirectional, articulation in vitro. This work for the first time enables investigation of a relationship betweenclinical wear conditions, as determined by patient gait path, and the mechanical and structural changes that occur within theUHMWPE acetabular component. Individual patients’ wear paths were determined prior to revision operation from hip jointkinematics measured by clinical gait analysis. The material properties of the acetabular components removed during the revisionoperation were subsequently analysed. A technique using Fourier transform infra- red analysis (FTIR) was developed to quantifythe orientation of the individual UHMWPE lamellae. This study shows that there is a direct relationship between a patient’s clinicalgait path and the molecular properties of their UHMWPE acetabular socket. Patient kinematics are an important factor affectingthe wear and long-term biocompatibility of UHMWPE used as a bearing surface in THR.r 2005 Elsevier Ltd. All rights reserved.

M3 - Article

VL - 26

SP - 4993

EP - 5001

JO - Biomaterials

T2 - Biomaterials

JF - Biomaterials

SN - 0142-9612

ER -

Davey S, Orr JF, Buchanan FJ, Nixon JR, Bennett D. The effect of patient gait on the material properties of UHMWPEin hip replacements. Biomaterials. 2005 Mar 1;26:4993-5001.