The anthracen-9-ylmethyloxy unit: An underperforming motif within the fluorescent PET (photoinduced electron transfer) sensing framework

DC Magri, JF Callan, AP de Silva, DB Fox, ND McClenaghan, KRAS Sandanayake

Research output: Contribution to journalArticle

33 Citations (Scopus)

Abstract

Compound 2, which was designed to act as a fluorescent sensor for calcium according to the PET (Photoinduced Electron Transfer) principle, shows a relatively small Ca2+-induced fluorescence enhancement factor (FE) of 1.8 whereas its close relative 1 is known to display a far higher FE value of 16. Though designed as fluorescent PET sensors for solvent polarity, compounds 5 and 6 also show negligible fluorescence enhancement as their environments are made progressively less polar even though their relatives 3 and 4 show limiting FE values of 53 and 3, respectively. Indeed, 3 and 4 are useful since they are fluorescent sensors for solvent polarity without being affected by Bronsted acidity. The poor sensory performance of 2, 5, and 6 relative to their cousins is attributed to the presence of an oxygen proximal to the 9-position of an anthracene unit, which opens up a CT (charge transfer) channel. Normal PET sensing service is resumed when the offending oxygen is deleted.
LanguageEnglish
Pages769-775
JournalJournal of Fluorescence
Volume15
Issue number5
DOIs
Publication statusPublished - Sep 2005

Fingerprint

Fluorescence
Electrons
Sensors
Oxygen
Acidity
Charge transfer
Calcium

Cite this

Magri, DC ; Callan, JF ; de Silva, AP ; Fox, DB ; McClenaghan, ND ; Sandanayake, KRAS. / The anthracen-9-ylmethyloxy unit: An underperforming motif within the fluorescent PET (photoinduced electron transfer) sensing framework. In: Journal of Fluorescence. 2005 ; Vol. 15, No. 5. pp. 769-775.
@article{75e88841149d496caf7d89547bf7faa2,
title = "The anthracen-9-ylmethyloxy unit: An underperforming motif within the fluorescent PET (photoinduced electron transfer) sensing framework",
abstract = "Compound 2, which was designed to act as a fluorescent sensor for calcium according to the PET (Photoinduced Electron Transfer) principle, shows a relatively small Ca2+-induced fluorescence enhancement factor (FE) of 1.8 whereas its close relative 1 is known to display a far higher FE value of 16. Though designed as fluorescent PET sensors for solvent polarity, compounds 5 and 6 also show negligible fluorescence enhancement as their environments are made progressively less polar even though their relatives 3 and 4 show limiting FE values of 53 and 3, respectively. Indeed, 3 and 4 are useful since they are fluorescent sensors for solvent polarity without being affected by Bronsted acidity. The poor sensory performance of 2, 5, and 6 relative to their cousins is attributed to the presence of an oxygen proximal to the 9-position of an anthracene unit, which opens up a CT (charge transfer) channel. Normal PET sensing service is resumed when the offending oxygen is deleted.",
author = "DC Magri and JF Callan and {de Silva}, AP and DB Fox and ND McClenaghan and KRAS Sandanayake",
year = "2005",
month = "9",
doi = "10.1007/s10895-005-2986-4",
language = "English",
volume = "15",
pages = "769--775",
journal = "Journal of Fluorescence",
issn = "1053-0509",
number = "5",

}

The anthracen-9-ylmethyloxy unit: An underperforming motif within the fluorescent PET (photoinduced electron transfer) sensing framework. / Magri, DC; Callan, JF; de Silva, AP; Fox, DB; McClenaghan, ND; Sandanayake, KRAS.

In: Journal of Fluorescence, Vol. 15, No. 5, 09.2005, p. 769-775.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The anthracen-9-ylmethyloxy unit: An underperforming motif within the fluorescent PET (photoinduced electron transfer) sensing framework

AU - Magri, DC

AU - Callan, JF

AU - de Silva, AP

AU - Fox, DB

AU - McClenaghan, ND

AU - Sandanayake, KRAS

PY - 2005/9

Y1 - 2005/9

N2 - Compound 2, which was designed to act as a fluorescent sensor for calcium according to the PET (Photoinduced Electron Transfer) principle, shows a relatively small Ca2+-induced fluorescence enhancement factor (FE) of 1.8 whereas its close relative 1 is known to display a far higher FE value of 16. Though designed as fluorescent PET sensors for solvent polarity, compounds 5 and 6 also show negligible fluorescence enhancement as their environments are made progressively less polar even though their relatives 3 and 4 show limiting FE values of 53 and 3, respectively. Indeed, 3 and 4 are useful since they are fluorescent sensors for solvent polarity without being affected by Bronsted acidity. The poor sensory performance of 2, 5, and 6 relative to their cousins is attributed to the presence of an oxygen proximal to the 9-position of an anthracene unit, which opens up a CT (charge transfer) channel. Normal PET sensing service is resumed when the offending oxygen is deleted.

AB - Compound 2, which was designed to act as a fluorescent sensor for calcium according to the PET (Photoinduced Electron Transfer) principle, shows a relatively small Ca2+-induced fluorescence enhancement factor (FE) of 1.8 whereas its close relative 1 is known to display a far higher FE value of 16. Though designed as fluorescent PET sensors for solvent polarity, compounds 5 and 6 also show negligible fluorescence enhancement as their environments are made progressively less polar even though their relatives 3 and 4 show limiting FE values of 53 and 3, respectively. Indeed, 3 and 4 are useful since they are fluorescent sensors for solvent polarity without being affected by Bronsted acidity. The poor sensory performance of 2, 5, and 6 relative to their cousins is attributed to the presence of an oxygen proximal to the 9-position of an anthracene unit, which opens up a CT (charge transfer) channel. Normal PET sensing service is resumed when the offending oxygen is deleted.

U2 - 10.1007/s10895-005-2986-4

DO - 10.1007/s10895-005-2986-4

M3 - Article

VL - 15

SP - 769

EP - 775

JO - Journal of Fluorescence

T2 - Journal of Fluorescence

JF - Journal of Fluorescence

SN - 1053-0509

IS - 5

ER -