Review of the CE-MS platform as a powerful alternative to conventional couplings in bio-omics and target-based applications

Virginia Rodriguez Robledo, Franklin Smyth

    Research output: Contribution to journalArticle

    35 Citations (Scopus)

    Abstract

    Many recent papers and reviews have confirmed the powerful coupling between CE and MS due to efficient and selective separation in combination with selective detection allowing detailed characterization of many biomolecules. It is known that CE-MS is an increasingly used and sought after technique for analysis in different fields such as environmental science, food analysis, biotechnology, pharmaceutical analysis, biomedical science, forensic science, toxicology, and genetic analysis. CE-MS is particularly used in bio-omic applications (proteomic, metabolomic, and also genomic applications) for the determination of biomarkers, disease diagnosis, and therapeutic treatment monitoring. Biomarker qualification, clinical proteomics, and its implementation in routine clinical analysis have certain limitations associated with reproducibility and analytical robustness. However, CE-MS has been successfully used in numerous clinical applications in recent years when compared with other platforms. The main advantage lies in the availability of large comparable datasets that were all obtained by using the same procedure for sample preparation, analysis, and subsequent data evaluation. The scope of this review is to discuss the performance of CE-MS as a platform for bio-omics analysis and target-based applications focusing on quadrupole (Q), IT, and TOF analyzers, and the types of bioapplications that apply to the particular analyzers. Papers and reviews that were published in 2012 and 2013 with relevant CE-MS applications are considered in this review.
    LanguageEnglish
    Pages2292-2308
    JournalElectrophoresis
    Volume35
    Issue number16, SI
    Early online date31 Jan 2014
    DOIs
    Publication statusPublished - Aug 2014

    Fingerprint

    Biomarkers
    Biomolecules
    Biotechnology
    Availability
    Monitoring
    Pharmaceutical Preparations
    Proteomics
    Forensic science
    Metabolomics

    Cite this

    @article{135a6aa9269e4fe0ac0f3e5c4106715e,
    title = "Review of the CE-MS platform as a powerful alternative to conventional couplings in bio-omics and target-based applications",
    abstract = "Many recent papers and reviews have confirmed the powerful coupling between CE and MS due to efficient and selective separation in combination with selective detection allowing detailed characterization of many biomolecules. It is known that CE-MS is an increasingly used and sought after technique for analysis in different fields such as environmental science, food analysis, biotechnology, pharmaceutical analysis, biomedical science, forensic science, toxicology, and genetic analysis. CE-MS is particularly used in bio-omic applications (proteomic, metabolomic, and also genomic applications) for the determination of biomarkers, disease diagnosis, and therapeutic treatment monitoring. Biomarker qualification, clinical proteomics, and its implementation in routine clinical analysis have certain limitations associated with reproducibility and analytical robustness. However, CE-MS has been successfully used in numerous clinical applications in recent years when compared with other platforms. The main advantage lies in the availability of large comparable datasets that were all obtained by using the same procedure for sample preparation, analysis, and subsequent data evaluation. The scope of this review is to discuss the performance of CE-MS as a platform for bio-omics analysis and target-based applications focusing on quadrupole (Q), IT, and TOF analyzers, and the types of bioapplications that apply to the particular analyzers. Papers and reviews that were published in 2012 and 2013 with relevant CE-MS applications are considered in this review.",
    author = "{Rodriguez Robledo}, Virginia and Franklin Smyth",
    year = "2014",
    month = "8",
    doi = "10.1002/elps.201300561",
    language = "English",
    volume = "35",
    pages = "2292--2308",
    journal = "Electrophoresis",
    issn = "0173-0835",
    number = "16, SI",

    }

    Review of the CE-MS platform as a powerful alternative to conventional couplings in bio-omics and target-based applications. / Rodriguez Robledo, Virginia; Smyth, Franklin.

    In: Electrophoresis, Vol. 35, No. 16, SI, 08.2014, p. 2292-2308.

    Research output: Contribution to journalArticle

    TY - JOUR

    T1 - Review of the CE-MS platform as a powerful alternative to conventional couplings in bio-omics and target-based applications

    AU - Rodriguez Robledo, Virginia

    AU - Smyth, Franklin

    PY - 2014/8

    Y1 - 2014/8

    N2 - Many recent papers and reviews have confirmed the powerful coupling between CE and MS due to efficient and selective separation in combination with selective detection allowing detailed characterization of many biomolecules. It is known that CE-MS is an increasingly used and sought after technique for analysis in different fields such as environmental science, food analysis, biotechnology, pharmaceutical analysis, biomedical science, forensic science, toxicology, and genetic analysis. CE-MS is particularly used in bio-omic applications (proteomic, metabolomic, and also genomic applications) for the determination of biomarkers, disease diagnosis, and therapeutic treatment monitoring. Biomarker qualification, clinical proteomics, and its implementation in routine clinical analysis have certain limitations associated with reproducibility and analytical robustness. However, CE-MS has been successfully used in numerous clinical applications in recent years when compared with other platforms. The main advantage lies in the availability of large comparable datasets that were all obtained by using the same procedure for sample preparation, analysis, and subsequent data evaluation. The scope of this review is to discuss the performance of CE-MS as a platform for bio-omics analysis and target-based applications focusing on quadrupole (Q), IT, and TOF analyzers, and the types of bioapplications that apply to the particular analyzers. Papers and reviews that were published in 2012 and 2013 with relevant CE-MS applications are considered in this review.

    AB - Many recent papers and reviews have confirmed the powerful coupling between CE and MS due to efficient and selective separation in combination with selective detection allowing detailed characterization of many biomolecules. It is known that CE-MS is an increasingly used and sought after technique for analysis in different fields such as environmental science, food analysis, biotechnology, pharmaceutical analysis, biomedical science, forensic science, toxicology, and genetic analysis. CE-MS is particularly used in bio-omic applications (proteomic, metabolomic, and also genomic applications) for the determination of biomarkers, disease diagnosis, and therapeutic treatment monitoring. Biomarker qualification, clinical proteomics, and its implementation in routine clinical analysis have certain limitations associated with reproducibility and analytical robustness. However, CE-MS has been successfully used in numerous clinical applications in recent years when compared with other platforms. The main advantage lies in the availability of large comparable datasets that were all obtained by using the same procedure for sample preparation, analysis, and subsequent data evaluation. The scope of this review is to discuss the performance of CE-MS as a platform for bio-omics analysis and target-based applications focusing on quadrupole (Q), IT, and TOF analyzers, and the types of bioapplications that apply to the particular analyzers. Papers and reviews that were published in 2012 and 2013 with relevant CE-MS applications are considered in this review.

    U2 - 10.1002/elps.201300561

    DO - 10.1002/elps.201300561

    M3 - Article

    VL - 35

    SP - 2292

    EP - 2308

    JO - Electrophoresis

    T2 - Electrophoresis

    JF - Electrophoresis

    SN - 0173-0835

    IS - 16, SI

    ER -