The response of an Electrochemical Impedance Spectroscopy (EIS) sensor using DNA aptamers is affected by many factors, such as DNA density, charge and conformational changes upon DNA-target binding, and buffer conditions. We report here for the first time on the optimisation of an EIS aptamer-based sensor by using Quartz Crystal Microbalance with Dissipation mode (QCM-D). As a case study, we employed a DNA aptamer against Prostate-Specific Antigen (PSA). PSA detection was achieved by functionalising the gold sensor surface via thiol chemistry with different ratios of thiolated-DNA aptamer and 6-mercapto-1-hexanol (MCH) used as spacer molecules. PSA binding efficiency can be monitored by measuring QCM-D signals which not only provide information about the mass of PSA bound on the sensor surface, but also crucial information about the aptamer conformation and layer hydration. Data generated through QCM-D analysis provided the optimal conditions in terms of aptamer/MCH ratio to maximise the PSA binding. The ratio of 1:200 for DNA aptamer/spacer molecule was found to be optimal for ensuring maximum PSA binding. However, this study showed how a maximum analyte binding does not necessarily correspond to a maximum EIS response, which revealed to be enhanced if a ratio of 1:100 for DNA aptamer/spacer molecule was used. Moreover, by monitoring the QCM-D signal, for the first time, a value of the dissociation constant (Kd), equal to 37 nM, was found for the PSA DNA aptamer towards its target. The combination of QCM-D with EIS techniques provides further insight into the effects of mass loading and charge effects that govern the response of an EIS aptasensor, serving as a valuable support for future EIS aptamer-based applications.

LanguageEnglish
Pages369-375
Number of pages7
JournalSensors and Actuators, B: Chemical
Volume220
DOIs
Publication statusPublished - 30 May 2015

Fingerprint

Nucleotide Aptamers
Quartz crystal microbalances
Prostate-Specific Antigen
quartz crystals
Electrochemical impedance spectroscopy
microbalances
antigens
Antigens
DNA
dissipation
deoxyribonucleic acid
impedance
optimization
spectroscopy
spacers
Sensors
sensors
Molecules
molecules
Charge density

Keywords

  • DNA aptamer
  • Electrochemical Impedance Spectroscopy
  • Prostate cancer
  • Quartz Crystal Microbalance with Dissipation

Cite this

Formisano, Nello ; Jolly, Pawan ; Bhalla, Nikhil ; Cromhout, Mary ; Flanagan, Shane P. ; Fogel, Ronen ; Limson, Janice L. ; Estrela, Pedro. / Optimisation of an electrochemical impedance spectroscopy aptasensor by exploiting quartz crystal microbalance with dissipation signals. In: Sensors and Actuators, B: Chemical. 2015 ; Vol. 220. pp. 369-375.
@article{3a9dd02516d4431486f4b5165e887441,
title = "Optimisation of an electrochemical impedance spectroscopy aptasensor by exploiting quartz crystal microbalance with dissipation signals",
abstract = "The response of an Electrochemical Impedance Spectroscopy (EIS) sensor using DNA aptamers is affected by many factors, such as DNA density, charge and conformational changes upon DNA-target binding, and buffer conditions. We report here for the first time on the optimisation of an EIS aptamer-based sensor by using Quartz Crystal Microbalance with Dissipation mode (QCM-D). As a case study, we employed a DNA aptamer against Prostate-Specific Antigen (PSA). PSA detection was achieved by functionalising the gold sensor surface via thiol chemistry with different ratios of thiolated-DNA aptamer and 6-mercapto-1-hexanol (MCH) used as spacer molecules. PSA binding efficiency can be monitored by measuring QCM-D signals which not only provide information about the mass of PSA bound on the sensor surface, but also crucial information about the aptamer conformation and layer hydration. Data generated through QCM-D analysis provided the optimal conditions in terms of aptamer/MCH ratio to maximise the PSA binding. The ratio of 1:200 for DNA aptamer/spacer molecule was found to be optimal for ensuring maximum PSA binding. However, this study showed how a maximum analyte binding does not necessarily correspond to a maximum EIS response, which revealed to be enhanced if a ratio of 1:100 for DNA aptamer/spacer molecule was used. Moreover, by monitoring the QCM-D signal, for the first time, a value of the dissociation constant (Kd), equal to 37 nM, was found for the PSA DNA aptamer towards its target. The combination of QCM-D with EIS techniques provides further insight into the effects of mass loading and charge effects that govern the response of an EIS aptasensor, serving as a valuable support for future EIS aptamer-based applications.",
keywords = "DNA aptamer, Electrochemical Impedance Spectroscopy, Prostate cancer, Quartz Crystal Microbalance with Dissipation",
author = "Nello Formisano and Pawan Jolly and Nikhil Bhalla and Mary Cromhout and Flanagan, {Shane P.} and Ronen Fogel and Limson, {Janice L.} and Pedro Estrela",
year = "2015",
month = "5",
day = "30",
doi = "10.1016/j.snb.2015.05.049",
language = "English",
volume = "220",
pages = "369--375",
journal = "Sensors and Actuators B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",

}

Optimisation of an electrochemical impedance spectroscopy aptasensor by exploiting quartz crystal microbalance with dissipation signals. / Formisano, Nello; Jolly, Pawan; Bhalla, Nikhil; Cromhout, Mary; Flanagan, Shane P.; Fogel, Ronen; Limson, Janice L.; Estrela, Pedro.

In: Sensors and Actuators, B: Chemical, Vol. 220, 30.05.2015, p. 369-375.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Optimisation of an electrochemical impedance spectroscopy aptasensor by exploiting quartz crystal microbalance with dissipation signals

AU - Formisano, Nello

AU - Jolly, Pawan

AU - Bhalla, Nikhil

AU - Cromhout, Mary

AU - Flanagan, Shane P.

AU - Fogel, Ronen

AU - Limson, Janice L.

AU - Estrela, Pedro

PY - 2015/5/30

Y1 - 2015/5/30

N2 - The response of an Electrochemical Impedance Spectroscopy (EIS) sensor using DNA aptamers is affected by many factors, such as DNA density, charge and conformational changes upon DNA-target binding, and buffer conditions. We report here for the first time on the optimisation of an EIS aptamer-based sensor by using Quartz Crystal Microbalance with Dissipation mode (QCM-D). As a case study, we employed a DNA aptamer against Prostate-Specific Antigen (PSA). PSA detection was achieved by functionalising the gold sensor surface via thiol chemistry with different ratios of thiolated-DNA aptamer and 6-mercapto-1-hexanol (MCH) used as spacer molecules. PSA binding efficiency can be monitored by measuring QCM-D signals which not only provide information about the mass of PSA bound on the sensor surface, but also crucial information about the aptamer conformation and layer hydration. Data generated through QCM-D analysis provided the optimal conditions in terms of aptamer/MCH ratio to maximise the PSA binding. The ratio of 1:200 for DNA aptamer/spacer molecule was found to be optimal for ensuring maximum PSA binding. However, this study showed how a maximum analyte binding does not necessarily correspond to a maximum EIS response, which revealed to be enhanced if a ratio of 1:100 for DNA aptamer/spacer molecule was used. Moreover, by monitoring the QCM-D signal, for the first time, a value of the dissociation constant (Kd), equal to 37 nM, was found for the PSA DNA aptamer towards its target. The combination of QCM-D with EIS techniques provides further insight into the effects of mass loading and charge effects that govern the response of an EIS aptasensor, serving as a valuable support for future EIS aptamer-based applications.

AB - The response of an Electrochemical Impedance Spectroscopy (EIS) sensor using DNA aptamers is affected by many factors, such as DNA density, charge and conformational changes upon DNA-target binding, and buffer conditions. We report here for the first time on the optimisation of an EIS aptamer-based sensor by using Quartz Crystal Microbalance with Dissipation mode (QCM-D). As a case study, we employed a DNA aptamer against Prostate-Specific Antigen (PSA). PSA detection was achieved by functionalising the gold sensor surface via thiol chemistry with different ratios of thiolated-DNA aptamer and 6-mercapto-1-hexanol (MCH) used as spacer molecules. PSA binding efficiency can be monitored by measuring QCM-D signals which not only provide information about the mass of PSA bound on the sensor surface, but also crucial information about the aptamer conformation and layer hydration. Data generated through QCM-D analysis provided the optimal conditions in terms of aptamer/MCH ratio to maximise the PSA binding. The ratio of 1:200 for DNA aptamer/spacer molecule was found to be optimal for ensuring maximum PSA binding. However, this study showed how a maximum analyte binding does not necessarily correspond to a maximum EIS response, which revealed to be enhanced if a ratio of 1:100 for DNA aptamer/spacer molecule was used. Moreover, by monitoring the QCM-D signal, for the first time, a value of the dissociation constant (Kd), equal to 37 nM, was found for the PSA DNA aptamer towards its target. The combination of QCM-D with EIS techniques provides further insight into the effects of mass loading and charge effects that govern the response of an EIS aptasensor, serving as a valuable support for future EIS aptamer-based applications.

KW - DNA aptamer

KW - Electrochemical Impedance Spectroscopy

KW - Prostate cancer

KW - Quartz Crystal Microbalance with Dissipation

UR - http://www.scopus.com/inward/record.url?scp=84936746835&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2015.05.049

DO - 10.1016/j.snb.2015.05.049

M3 - Article

VL - 220

SP - 369

EP - 375

JO - Sensors and Actuators B: Chemical

T2 - Sensors and Actuators B: Chemical

JF - Sensors and Actuators B: Chemical

SN - 0925-4005

ER -