Optical coherence tomography measurements of the fresh porcine eye and response of the outer coats of the eye to volume increase

Magdelena Asejczyk-Widlicka, Ronald A. Schachar, Barbara K. Pierscionek

    Research output: Contribution to journalArticle

    17 Citations (Scopus)

    Abstract

    Corneal and scleral thickness and anterior chamber dimensions are required for understanding developmental and pathological processes. Parameters of the eyeball are also required to calculate optical and material properties. As the eyeball resembles a pressure vessel, it has been suggested that elasticity of the cornea and sclera could be calculated from the measurements of thickness. Baseline corneal and scleral thicknesses and anterior chamber dimensions and how these change with incremental increases of intraocular fluid are measured in fresh porcine eyes using the Visante OCT (optical coherence tomography). At baseline, corneal thickness is almost constant. Anterior scleral thickness is variable, decreasing from 0.91 +/- 0.07 mm near the limbus to a minimum of 0.58 +/- 0.13. Posterior scleral thickness is more constant with an average of 0.78 +/- 0.09 mm. Near the optic nerve the thickness increases to 1.00 +/- 0.09 mm. Average baseline anterior chamber angle, diameter, and depth were found to be 33.15 +/- 4.91 deg, 13.60 +/- 0.38 mm, and 2.13 +/- 0.22 mm, respectively. After fluid injections, maximum changes in corneal and scleral thicknesses were 9 to 10 and 1 to 3%, respectively. Anterior chamber angle and depth decreased slightly but significantly. Changes in the eyeball coats with fluid injections, indicate that the pressure vessel model can be applied to the eye to calculate corneal and scleral elasticities. (C) 2008 Society of Photo-Optical Instrumentation Engineers.
    LanguageEnglish
    Pages024002
    JournalJournal of Biomedical Optics
    Volume13
    Issue number2
    DOIs
    Publication statusPublished - Mar 2008

    Fingerprint

    Optical Coherence Tomography
    Anterior Chamber
    Swine
    Elasticity
    Pressure
    Sclera
    Injections
    Aqueous Humor
    Pathologic Processes
    Optic Nerve
    Cornea

    Cite this

    Asejczyk-Widlicka, Magdelena ; Schachar, Ronald A. ; Pierscionek, Barbara K. / Optical coherence tomography measurements of the fresh porcine eye and response of the outer coats of the eye to volume increase. In: Journal of Biomedical Optics. 2008 ; Vol. 13, No. 2. pp. 024002.
    @article{6a77845501764fc2911aa1f6c435069a,
    title = "Optical coherence tomography measurements of the fresh porcine eye and response of the outer coats of the eye to volume increase",
    abstract = "Corneal and scleral thickness and anterior chamber dimensions are required for understanding developmental and pathological processes. Parameters of the eyeball are also required to calculate optical and material properties. As the eyeball resembles a pressure vessel, it has been suggested that elasticity of the cornea and sclera could be calculated from the measurements of thickness. Baseline corneal and scleral thicknesses and anterior chamber dimensions and how these change with incremental increases of intraocular fluid are measured in fresh porcine eyes using the Visante OCT (optical coherence tomography). At baseline, corneal thickness is almost constant. Anterior scleral thickness is variable, decreasing from 0.91 +/- 0.07 mm near the limbus to a minimum of 0.58 +/- 0.13. Posterior scleral thickness is more constant with an average of 0.78 +/- 0.09 mm. Near the optic nerve the thickness increases to 1.00 +/- 0.09 mm. Average baseline anterior chamber angle, diameter, and depth were found to be 33.15 +/- 4.91 deg, 13.60 +/- 0.38 mm, and 2.13 +/- 0.22 mm, respectively. After fluid injections, maximum changes in corneal and scleral thicknesses were 9 to 10 and 1 to 3{\%}, respectively. Anterior chamber angle and depth decreased slightly but significantly. Changes in the eyeball coats with fluid injections, indicate that the pressure vessel model can be applied to the eye to calculate corneal and scleral elasticities. (C) 2008 Society of Photo-Optical Instrumentation Engineers.",
    author = "Magdelena Asejczyk-Widlicka and Schachar, {Ronald A.} and Pierscionek, {Barbara K.}",
    year = "2008",
    month = "3",
    doi = "10.1117/1.2907453",
    language = "English",
    volume = "13",
    pages = "024002",
    journal = "Journal of Biomedical Optics",
    issn = "1083-3668",
    publisher = "SPIE",
    number = "2",

    }

    Optical coherence tomography measurements of the fresh porcine eye and response of the outer coats of the eye to volume increase. / Asejczyk-Widlicka, Magdelena; Schachar, Ronald A.; Pierscionek, Barbara K.

    In: Journal of Biomedical Optics, Vol. 13, No. 2, 03.2008, p. 024002.

    Research output: Contribution to journalArticle

    TY - JOUR

    T1 - Optical coherence tomography measurements of the fresh porcine eye and response of the outer coats of the eye to volume increase

    AU - Asejczyk-Widlicka, Magdelena

    AU - Schachar, Ronald A.

    AU - Pierscionek, Barbara K.

    PY - 2008/3

    Y1 - 2008/3

    N2 - Corneal and scleral thickness and anterior chamber dimensions are required for understanding developmental and pathological processes. Parameters of the eyeball are also required to calculate optical and material properties. As the eyeball resembles a pressure vessel, it has been suggested that elasticity of the cornea and sclera could be calculated from the measurements of thickness. Baseline corneal and scleral thicknesses and anterior chamber dimensions and how these change with incremental increases of intraocular fluid are measured in fresh porcine eyes using the Visante OCT (optical coherence tomography). At baseline, corneal thickness is almost constant. Anterior scleral thickness is variable, decreasing from 0.91 +/- 0.07 mm near the limbus to a minimum of 0.58 +/- 0.13. Posterior scleral thickness is more constant with an average of 0.78 +/- 0.09 mm. Near the optic nerve the thickness increases to 1.00 +/- 0.09 mm. Average baseline anterior chamber angle, diameter, and depth were found to be 33.15 +/- 4.91 deg, 13.60 +/- 0.38 mm, and 2.13 +/- 0.22 mm, respectively. After fluid injections, maximum changes in corneal and scleral thicknesses were 9 to 10 and 1 to 3%, respectively. Anterior chamber angle and depth decreased slightly but significantly. Changes in the eyeball coats with fluid injections, indicate that the pressure vessel model can be applied to the eye to calculate corneal and scleral elasticities. (C) 2008 Society of Photo-Optical Instrumentation Engineers.

    AB - Corneal and scleral thickness and anterior chamber dimensions are required for understanding developmental and pathological processes. Parameters of the eyeball are also required to calculate optical and material properties. As the eyeball resembles a pressure vessel, it has been suggested that elasticity of the cornea and sclera could be calculated from the measurements of thickness. Baseline corneal and scleral thicknesses and anterior chamber dimensions and how these change with incremental increases of intraocular fluid are measured in fresh porcine eyes using the Visante OCT (optical coherence tomography). At baseline, corneal thickness is almost constant. Anterior scleral thickness is variable, decreasing from 0.91 +/- 0.07 mm near the limbus to a minimum of 0.58 +/- 0.13. Posterior scleral thickness is more constant with an average of 0.78 +/- 0.09 mm. Near the optic nerve the thickness increases to 1.00 +/- 0.09 mm. Average baseline anterior chamber angle, diameter, and depth were found to be 33.15 +/- 4.91 deg, 13.60 +/- 0.38 mm, and 2.13 +/- 0.22 mm, respectively. After fluid injections, maximum changes in corneal and scleral thicknesses were 9 to 10 and 1 to 3%, respectively. Anterior chamber angle and depth decreased slightly but significantly. Changes in the eyeball coats with fluid injections, indicate that the pressure vessel model can be applied to the eye to calculate corneal and scleral elasticities. (C) 2008 Society of Photo-Optical Instrumentation Engineers.

    U2 - 10.1117/1.2907453

    DO - 10.1117/1.2907453

    M3 - Article

    VL - 13

    SP - 024002

    JO - Journal of Biomedical Optics

    T2 - Journal of Biomedical Optics

    JF - Journal of Biomedical Optics

    SN - 1083-3668

    IS - 2

    ER -