Skip to main navigation Skip to search Skip to main content

Methodological development of a pneumatic artificial muscle-driven left ventricular simulator using interpretive structural modeling

Research output: Contribution to journal › Article › peer-review

6 Downloads (Pure)

Abstract

Mock circulation systems can replicate a wide range of cardiac operating scenarios, such as cardiovascular diseases, particularly muscular dysfunctions. These systems are operated by sophisticated control algorithms which require complex driver and data acquisition systems, whereas animal models raise ethical concerns. Therefore, there is a need for novel testbeds to overcome the challenges in the existing systems. The aim of this study is to develop a less complex and realistic left ventricular (LV) simulator. The Interpretive Structural Modeling (ISM) approach was utilized to evaluate different left ventricular actuation methods and materials. ISM revealed that the most suitable method to actuate the LV is using the pneumatic artificial muscles and latex rubber. The performance of the new LV simulator was evaluated for healthy and diseased conditions at 50, 60, 70 and 80 bpm heart rates. The experiments revealed that the beating LV simulator can generate average flow rates of up to 2.25 L/min. The actual human LV-like wall motion was also verified by the twisting angle on the apex of the beating LV simulator with 21 degrees of rotation and 11 mm of apex shortening. The prototyped beating LV simulator is a promising preliminary platform and may reach actual human LV’s hemodynamic and cardio-mechanical performance with further improvements.
Original languageEnglish
Article number e0355859
Pages (from-to)1-25
Number of pages25
JournalPLoS ONE
Volume21
Issue number8
Early online date13 Aug 2026
DOIs
Publication statusPublished (in print/issue) - 13 Aug 2026

Bibliographical note

© 2026 Baturalp, Bozkurt. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Data Availability Statement

All relevant data are within the manuscript and its Supporting information files.

Funding

The author(s) received no specific funding for this work.

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Humans
  • Heart Ventricles/physiopathology
  • Models, Cardiovascular
  • Ventricular Function, Left/physiology
  • Computer Simulation
  • Hemodynamics

Fingerprint

Dive into the research topics of 'Methodological development of a pneumatic artificial muscle-driven left ventricular simulator using interpretive structural modeling'. Together they form a unique fingerprint.

Cite this