Abstract
This paper aims to experimentally investigate the fire resistance of U-shaped hybrid composite beams protected by spay and paint insulations. Subjected to two and three hours of the Standard ISO fire, the flexural performance of 4.4m beams with/without imposed loadings was examined with respect to failure criteria such as deflection and deflection rate of the mid-span and temperatures measured in the steel section. The results demonstrated that the proposed configuration of the composite beam is able to achieve a very competitive 3-hour fire resistance rating in economical aspects.
Original language | English |
---|---|
Pages (from-to) | 379-388 |
Journal | Journal of Korean Society of Steel Construction |
Volume | 25 |
Issue number | 4 |
DOIs | |
Publication status | Published (in print/issue) - 1 Aug 2013 |