Abstract
The purpose of this study is to investigate the potential cause of fire in escalators due to the accumulation of dust particles. The primary inspiration for this research stems from the King’s Cross Underground fire, where 31 lives were lost. This tragic incident highlighted that dust accumulation can act as a seedbed for escalator fires, significantly contributing to fire development and spread (Desmond Fennell., 1988). Dust is defined as a mixture of unknown particles, regardless of their size, shape, or chemical composition. It may include textile fibres, paper, metals, human hair, and other materials, and typically accumulates in areas where materials are transported within buildings, such as escalators.
Dust particles are generally combustible and can ignite under certain conditions. For this study, dust samples from various locations on the escalator were collected and tested in the laboratory Fire Safety Engineering research and Technology Centre (FireSERT) located at Ulster University, Belfast. The building and region from which the dust particles were collected are kept confidential for privacy and security reasons. The experimental investigation involved small-scale testing using minimal quantities of dust and employed the following apparatus:
• Thermogravimetric Analysis (TGA)
• Fourier Transform Infrared Spectroscopy (FTIR)
• Cone Calorimeter
• Bomb Calorimeter
These tests allowed for the determination of the heat release rate, ignition time, and toxicity of the dust samples. The results were validated using Fire Dynamics Simulator (FDS) modelling and compared with reference values from the SFPE Fire Protection Handbook to identify materials with similar calorific values. A summary of findings is presented, along with recommendations based on the analysis.
Dust particles are generally combustible and can ignite under certain conditions. For this study, dust samples from various locations on the escalator were collected and tested in the laboratory Fire Safety Engineering research and Technology Centre (FireSERT) located at Ulster University, Belfast. The building and region from which the dust particles were collected are kept confidential for privacy and security reasons. The experimental investigation involved small-scale testing using minimal quantities of dust and employed the following apparatus:
• Thermogravimetric Analysis (TGA)
• Fourier Transform Infrared Spectroscopy (FTIR)
• Cone Calorimeter
• Bomb Calorimeter
These tests allowed for the determination of the heat release rate, ignition time, and toxicity of the dust samples. The results were validated using Fire Dynamics Simulator (FDS) modelling and compared with reference values from the SFPE Fire Protection Handbook to identify materials with similar calorific values. A summary of findings is presented, along with recommendations based on the analysis.
| Original language | English |
|---|---|
| Pages | 70-81 |
| Number of pages | 12 |
| DOIs | |
| Publication status | Published (in print/issue) - 25 Jun 2025 |
| Event | 5th International Fire Safety Symposium - Belfast, United Kingdom Duration: 25 Jun 2025 → 27 Jun 2025 |
Conference
| Conference | 5th International Fire Safety Symposium |
|---|---|
| Country/Territory | United Kingdom |
| City | Belfast |
| Period | 25/06/25 → 27/06/25 |
Keywords
- Experimental
- Dust escalator
- EU Code
- CFD Modelling
Fingerprint