Enhancing the antibacterial performance of orthopaedic implant materials by fibre laser surface engineering

Chi Wai Chan, Louise Carson, Graham C. Smith, Alessio Morelli, Seunghwan Lee

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

Implant failure caused by bacterial infection is extremely difficult to treat and usually requires the removal of the infected components. Despite the severe consequence of bacterial infection, research into bacterial infection of orthopaedic implants is still at an early stage compared to the effort on enhancing osseointegration, wear and corrosion resistance of implant materials. In this study, the effects of laser surface treatment on enhancing the antibacterial properties of commercially pure (CP) Ti (Grade 2), Ti6Al4V (Grade 5) and CoCrMo alloy implant materials were studied and compared for the first time. Laser surface treatment was performed by a continuous wave (CW) fibre laser with a near-infrared wavelength of 1064 nm in a nitrogen-containing environment. Staphylococcus aureus, commonly implicated in infection associated with orthopaedic implants, was used to investigate the antibacterial properties of the laser-treated surfaces. The surface roughness and topography of the laser-treated materials were analysed by a 2D roughness testing and by AFM. The surface morphologies before and after 24 h of bacterial cell culture were captured by SEM, and bacterial viability was determined using live/dead staining. Surface chemistry was analysed by XPS and surface wettability was measured using the sessile drop method. The findings of this study indicated that the laser-treated CP Ti and Ti6Al4V surfaces exhibited a noticeable reduction in bacterial adhesion and possessed a bactericidal effect. Such properties were attributable to the combined effects of reduced hydrophobicity, thicker and stable oxide films and presence of laser-induced nano-features. No similar antibacterial effect was observed in the laser-treated CoCrMo.

LanguageEnglish
Pages67-81
Number of pages15
JournalApplied Surface Science
Volume404
Early online date25 Jan 2017
DOIs
Publication statusPublished - 15 May 2017

Fingerprint

orthopedics
Orthopedics
Fiber lasers
fiber lasers
engineering
infectious diseases
Lasers
lasers
surface treatment
grade
Surface treatment
Surface roughness
staphylococcus
laser materials
continuous wave lasers
staining
hydrophobicity
wettability
Continuous wave lasers
wear resistance

Keywords

  • Antibacterial properties
  • Fibre laser
  • Laser surface engineering
  • Orthopaedic implants
  • Staphylococcus aureus

Cite this

Chan, Chi Wai ; Carson, Louise ; Smith, Graham C. ; Morelli, Alessio ; Lee, Seunghwan. / Enhancing the antibacterial performance of orthopaedic implant materials by fibre laser surface engineering. 2017 ; Vol. 404. pp. 67-81.
@article{5ae5136a95f74897a3438662b1c55393,
title = "Enhancing the antibacterial performance of orthopaedic implant materials by fibre laser surface engineering",
abstract = "Implant failure caused by bacterial infection is extremely difficult to treat and usually requires the removal of the infected components. Despite the severe consequence of bacterial infection, research into bacterial infection of orthopaedic implants is still at an early stage compared to the effort on enhancing osseointegration, wear and corrosion resistance of implant materials. In this study, the effects of laser surface treatment on enhancing the antibacterial properties of commercially pure (CP) Ti (Grade 2), Ti6Al4V (Grade 5) and CoCrMo alloy implant materials were studied and compared for the first time. Laser surface treatment was performed by a continuous wave (CW) fibre laser with a near-infrared wavelength of 1064 nm in a nitrogen-containing environment. Staphylococcus aureus, commonly implicated in infection associated with orthopaedic implants, was used to investigate the antibacterial properties of the laser-treated surfaces. The surface roughness and topography of the laser-treated materials were analysed by a 2D roughness testing and by AFM. The surface morphologies before and after 24 h of bacterial cell culture were captured by SEM, and bacterial viability was determined using live/dead staining. Surface chemistry was analysed by XPS and surface wettability was measured using the sessile drop method. The findings of this study indicated that the laser-treated CP Ti and Ti6Al4V surfaces exhibited a noticeable reduction in bacterial adhesion and possessed a bactericidal effect. Such properties were attributable to the combined effects of reduced hydrophobicity, thicker and stable oxide films and presence of laser-induced nano-features. No similar antibacterial effect was observed in the laser-treated CoCrMo.",
keywords = "Antibacterial properties, Fibre laser, Laser surface engineering, Orthopaedic implants, Staphylococcus aureus",
author = "Chan, {Chi Wai} and Louise Carson and Smith, {Graham C.} and Alessio Morelli and Seunghwan Lee",
note = "Available on QUB Pure portal.",
year = "2017",
month = "5",
day = "15",
doi = "10.1016/j.apsusc.2017.01.233",
language = "English",
volume = "404",
pages = "67--81",

}

Enhancing the antibacterial performance of orthopaedic implant materials by fibre laser surface engineering. / Chan, Chi Wai; Carson, Louise; Smith, Graham C.; Morelli, Alessio; Lee, Seunghwan.

Vol. 404, 15.05.2017, p. 67-81.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Enhancing the antibacterial performance of orthopaedic implant materials by fibre laser surface engineering

AU - Chan, Chi Wai

AU - Carson, Louise

AU - Smith, Graham C.

AU - Morelli, Alessio

AU - Lee, Seunghwan

N1 - Available on QUB Pure portal.

PY - 2017/5/15

Y1 - 2017/5/15

N2 - Implant failure caused by bacterial infection is extremely difficult to treat and usually requires the removal of the infected components. Despite the severe consequence of bacterial infection, research into bacterial infection of orthopaedic implants is still at an early stage compared to the effort on enhancing osseointegration, wear and corrosion resistance of implant materials. In this study, the effects of laser surface treatment on enhancing the antibacterial properties of commercially pure (CP) Ti (Grade 2), Ti6Al4V (Grade 5) and CoCrMo alloy implant materials were studied and compared for the first time. Laser surface treatment was performed by a continuous wave (CW) fibre laser with a near-infrared wavelength of 1064 nm in a nitrogen-containing environment. Staphylococcus aureus, commonly implicated in infection associated with orthopaedic implants, was used to investigate the antibacterial properties of the laser-treated surfaces. The surface roughness and topography of the laser-treated materials were analysed by a 2D roughness testing and by AFM. The surface morphologies before and after 24 h of bacterial cell culture were captured by SEM, and bacterial viability was determined using live/dead staining. Surface chemistry was analysed by XPS and surface wettability was measured using the sessile drop method. The findings of this study indicated that the laser-treated CP Ti and Ti6Al4V surfaces exhibited a noticeable reduction in bacterial adhesion and possessed a bactericidal effect. Such properties were attributable to the combined effects of reduced hydrophobicity, thicker and stable oxide films and presence of laser-induced nano-features. No similar antibacterial effect was observed in the laser-treated CoCrMo.

AB - Implant failure caused by bacterial infection is extremely difficult to treat and usually requires the removal of the infected components. Despite the severe consequence of bacterial infection, research into bacterial infection of orthopaedic implants is still at an early stage compared to the effort on enhancing osseointegration, wear and corrosion resistance of implant materials. In this study, the effects of laser surface treatment on enhancing the antibacterial properties of commercially pure (CP) Ti (Grade 2), Ti6Al4V (Grade 5) and CoCrMo alloy implant materials were studied and compared for the first time. Laser surface treatment was performed by a continuous wave (CW) fibre laser with a near-infrared wavelength of 1064 nm in a nitrogen-containing environment. Staphylococcus aureus, commonly implicated in infection associated with orthopaedic implants, was used to investigate the antibacterial properties of the laser-treated surfaces. The surface roughness and topography of the laser-treated materials were analysed by a 2D roughness testing and by AFM. The surface morphologies before and after 24 h of bacterial cell culture were captured by SEM, and bacterial viability was determined using live/dead staining. Surface chemistry was analysed by XPS and surface wettability was measured using the sessile drop method. The findings of this study indicated that the laser-treated CP Ti and Ti6Al4V surfaces exhibited a noticeable reduction in bacterial adhesion and possessed a bactericidal effect. Such properties were attributable to the combined effects of reduced hydrophobicity, thicker and stable oxide films and presence of laser-induced nano-features. No similar antibacterial effect was observed in the laser-treated CoCrMo.

KW - Antibacterial properties

KW - Fibre laser

KW - Laser surface engineering

KW - Orthopaedic implants

KW - Staphylococcus aureus

UR - http://www.scopus.com/inward/record.url?scp=85011571422&partnerID=8YFLogxK

U2 - 10.1016/j.apsusc.2017.01.233

DO - 10.1016/j.apsusc.2017.01.233

M3 - Article

VL - 404

SP - 67

EP - 81

ER -