DEFLAGRATIONS OF LOCALISED HOMOGENEOUS AND INHOMOGENEOUS HYDROGEN-AIR MIXTURES IN ENCLOSURES

D. Makarov, P. Hooker, M. Kuznetsov, V Molkov

Research output: Contribution to journalArticle

Abstract

Two original models for use as novel tools for the design of hydrogen-air deflagration mitigation systems for equipment and enclosures are presented. The first model describes deflagrations of localised hydrogen-air mixtures in a closed space such as a pressure vessel or a well-sealed building while the second model defines safety requirements for vented deflagrations of localised mixtures in an enclosure. Examples of localised mixtures include ‘pockets’ of gas within an enclosure as well as stratified gas distributions which are especially relevant to hydrogen releases. The thermodynamic model for closed spaces is validated against experiments available from the literature. This model is used to estimate the maximum hydrogen inventory in a closed space assuming the closed space can withstand a maximum overpressure of 10 kPa without damage (this is typical of many civil structures). The upper limit for hydrogen inventory in a confined space to prevent damage is found to be equivalent to 7.9% of the closed space being filled with 4% hydrogen. If the hydrogen inventory in a closed space is above this upper limit then the explosion has to be mitigated by the venting technique. For the first time an engineering correlation is presented that accounts for the phenomena affecting the overpressure from localised vented deflagrations, i.e. the turbulence generated by the flame front itself, the preferential diffusion in stretched flames, the fractal behaviour of the turbulent flame front surface, the initial flow turbulence in unburnt mixture, and the increase of the flame surface area due to the shape of an enclosure. Validation of the new vented deflagration model developed at Ulster has been carried out against 25 experiments with lean stratified hydrogen-air mixtures performed by the Health and Safety Executive (UK) and Karlsruhe Institute of Technology (Germany).
LanguageEnglish
PagesXXXX-XXXX
JournalInternational Journal of Hydrogen Energy
Volume43
Publication statusAccepted/In press - 23 Mar 2018

Fingerprint

deflagration
enclosure
air
hydrogen
overpressure
flame propagation
flames
safety
turbulence
damage
venting
pressure vessels
turbulent flames
Germany
gases
health
explosions
fractals
engineering
thermodynamics

Keywords

  • Hydrogen
  • localised flammable mixture
  • vented deflagration
  • inhomogeneous mixture
  • engineering correlation
  • validation

Cite this

@article{07b14dab7ce4482fb83442da8208474e,
title = "DEFLAGRATIONS OF LOCALISED HOMOGENEOUS AND INHOMOGENEOUS HYDROGEN-AIR MIXTURES IN ENCLOSURES",
abstract = "Two original models for use as novel tools for the design of hydrogen-air deflagration mitigation systems for equipment and enclosures are presented. The first model describes deflagrations of localised hydrogen-air mixtures in a closed space such as a pressure vessel or a well-sealed building while the second model defines safety requirements for vented deflagrations of localised mixtures in an enclosure. Examples of localised mixtures include ‘pockets’ of gas within an enclosure as well as stratified gas distributions which are especially relevant to hydrogen releases. The thermodynamic model for closed spaces is validated against experiments available from the literature. This model is used to estimate the maximum hydrogen inventory in a closed space assuming the closed space can withstand a maximum overpressure of 10 kPa without damage (this is typical of many civil structures). The upper limit for hydrogen inventory in a confined space to prevent damage is found to be equivalent to 7.9{\%} of the closed space being filled with 4{\%} hydrogen. If the hydrogen inventory in a closed space is above this upper limit then the explosion has to be mitigated by the venting technique. For the first time an engineering correlation is presented that accounts for the phenomena affecting the overpressure from localised vented deflagrations, i.e. the turbulence generated by the flame front itself, the preferential diffusion in stretched flames, the fractal behaviour of the turbulent flame front surface, the initial flow turbulence in unburnt mixture, and the increase of the flame surface area due to the shape of an enclosure. Validation of the new vented deflagration model developed at Ulster has been carried out against 25 experiments with lean stratified hydrogen-air mixtures performed by the Health and Safety Executive (UK) and Karlsruhe Institute of Technology (Germany).",
keywords = "Hydrogen, localised flammable mixture, vented deflagration, inhomogeneous mixture, engineering correlation, validation",
author = "D. Makarov and P. Hooker and M. Kuznetsov and V Molkov",
year = "2018",
month = "3",
day = "23",
language = "English",
volume = "43",
pages = "XXXX--XXXX",
journal = "International Journal of Hydrogen Energy",
issn = "0360-3199",
publisher = "Elsevier",

}

DEFLAGRATIONS OF LOCALISED HOMOGENEOUS AND INHOMOGENEOUS HYDROGEN-AIR MIXTURES IN ENCLOSURES. / Makarov, D.; Hooker, P.; Kuznetsov, M.; Molkov, V.

In: International Journal of Hydrogen Energy, Vol. 43, 23.03.2018, p. XXXX-XXXX.

Research output: Contribution to journalArticle

TY - JOUR

T1 - DEFLAGRATIONS OF LOCALISED HOMOGENEOUS AND INHOMOGENEOUS HYDROGEN-AIR MIXTURES IN ENCLOSURES

AU - Makarov, D.

AU - Hooker, P.

AU - Kuznetsov, M.

AU - Molkov, V

PY - 2018/3/23

Y1 - 2018/3/23

N2 - Two original models for use as novel tools for the design of hydrogen-air deflagration mitigation systems for equipment and enclosures are presented. The first model describes deflagrations of localised hydrogen-air mixtures in a closed space such as a pressure vessel or a well-sealed building while the second model defines safety requirements for vented deflagrations of localised mixtures in an enclosure. Examples of localised mixtures include ‘pockets’ of gas within an enclosure as well as stratified gas distributions which are especially relevant to hydrogen releases. The thermodynamic model for closed spaces is validated against experiments available from the literature. This model is used to estimate the maximum hydrogen inventory in a closed space assuming the closed space can withstand a maximum overpressure of 10 kPa without damage (this is typical of many civil structures). The upper limit for hydrogen inventory in a confined space to prevent damage is found to be equivalent to 7.9% of the closed space being filled with 4% hydrogen. If the hydrogen inventory in a closed space is above this upper limit then the explosion has to be mitigated by the venting technique. For the first time an engineering correlation is presented that accounts for the phenomena affecting the overpressure from localised vented deflagrations, i.e. the turbulence generated by the flame front itself, the preferential diffusion in stretched flames, the fractal behaviour of the turbulent flame front surface, the initial flow turbulence in unburnt mixture, and the increase of the flame surface area due to the shape of an enclosure. Validation of the new vented deflagration model developed at Ulster has been carried out against 25 experiments with lean stratified hydrogen-air mixtures performed by the Health and Safety Executive (UK) and Karlsruhe Institute of Technology (Germany).

AB - Two original models for use as novel tools for the design of hydrogen-air deflagration mitigation systems for equipment and enclosures are presented. The first model describes deflagrations of localised hydrogen-air mixtures in a closed space such as a pressure vessel or a well-sealed building while the second model defines safety requirements for vented deflagrations of localised mixtures in an enclosure. Examples of localised mixtures include ‘pockets’ of gas within an enclosure as well as stratified gas distributions which are especially relevant to hydrogen releases. The thermodynamic model for closed spaces is validated against experiments available from the literature. This model is used to estimate the maximum hydrogen inventory in a closed space assuming the closed space can withstand a maximum overpressure of 10 kPa without damage (this is typical of many civil structures). The upper limit for hydrogen inventory in a confined space to prevent damage is found to be equivalent to 7.9% of the closed space being filled with 4% hydrogen. If the hydrogen inventory in a closed space is above this upper limit then the explosion has to be mitigated by the venting technique. For the first time an engineering correlation is presented that accounts for the phenomena affecting the overpressure from localised vented deflagrations, i.e. the turbulence generated by the flame front itself, the preferential diffusion in stretched flames, the fractal behaviour of the turbulent flame front surface, the initial flow turbulence in unburnt mixture, and the increase of the flame surface area due to the shape of an enclosure. Validation of the new vented deflagration model developed at Ulster has been carried out against 25 experiments with lean stratified hydrogen-air mixtures performed by the Health and Safety Executive (UK) and Karlsruhe Institute of Technology (Germany).

KW - Hydrogen

KW - localised flammable mixture

KW - vented deflagration

KW - inhomogeneous mixture

KW - engineering correlation

KW - validation

M3 - Article

VL - 43

SP - XXXX-XXXX

JO - International Journal of Hydrogen Energy

T2 - International Journal of Hydrogen Energy

JF - International Journal of Hydrogen Energy

SN - 0360-3199

ER -