Comparación de técnicas de cancelación de la actividad auricular en el ECG

MA Diaz, AI Hernandez, F Mora, OJ Escalona

Research output: Chapter in Book/Report/Conference proceedingChapter

Abstract

In English: In this paper, the performance-three QRS cancellation techniques compared to obtain a residual ECG information containing only atrial activity (AA), thereby facilitating detection of the P wave in the ECG and/or analysis of atrial arrhythmias. The methods are based on adaptive filters (AdF), neural networks (NN), and the space-time of an averaged beat for subsequent removal from the ECG signal, the comparison is made with reference to the results obtained with the adaptive filtering method by Thakor. The results show that the methods based on NN and AdF are more robust to morphological changes of the signal and in the presence of noise than non-adaptive methods, also have the advantage that they do not require a pre-detection stage of QRST, however, for the average beat alignment method, best results are obtained when there are no QRS detection failures.In Spanish: En este trabajo se compara el rendimiento- de tres técnicas de cancelación de QRS con el fin de obtener un ECG residual que contenga solo información de la actividad auricular (AA), facilitando así la detecci6n de la onda P del ECG y/o el análisis de arritmias auriculares. Los métodos se basan en filtros adaptativos (AdF), redes neurales (NN), y en el alineamiento espacio-temporal de un latido promedio para su posterior sustracción de la señal de ECG, la comparación se establece tomando como referencia los resultados obtenidos con el método de filtraje adaptativo de Thakor. Los resultados comprueban que los métodos adaptativos basados en NN y FA son más robustos frente a los cambios morfológicos de la señal y en presencia de ruido que los métodos no adaptativos, además tienen la ventaja de que no necesitan una etapa de detección previa de QRST, sin embargo con el método de alineación del latido promedio se obtienen mejores resultados cuando no hay falla de detección de QRS.
LanguageEnglish
Title of host publicationTendencias Actuales en Bioingenieria
Place of PublicationCaracas, Venezuela
Pages98-103
Publication statusPublished - 1 Sep 2000

Fingerprint

filter
hay
P-wave
method
detection
analysis
alignment
removal
comparison

Keywords

  • ECG denoising
  • atrial activity cancelation
  • atrial fibrilation ECG
  • QRS cancelation methods
  • arrhythmias
  • averaged QRS complex.

Cite this

Diaz, MA., Hernandez, AI., Mora, F., & Escalona, OJ. (2000). Comparación de técnicas de cancelación de la actividad auricular en el ECG. In Tendencias Actuales en Bioingenieria (pp. 98-103). Caracas, Venezuela.
Diaz, MA ; Hernandez, AI ; Mora, F ; Escalona, OJ. / Comparación de técnicas de cancelación de la actividad auricular en el ECG. Tendencias Actuales en Bioingenieria. Caracas, Venezuela, 2000. pp. 98-103
@inbook{f32ec8a545e04f7da7d67e2cc6e94884,
title = "Comparaci{\'o}n de t{\'e}cnicas de cancelaci{\'o}n de la actividad auricular en el ECG",
abstract = "In English: In this paper, the performance-three QRS cancellation techniques compared to obtain a residual ECG information containing only atrial activity (AA), thereby facilitating detection of the P wave in the ECG and/or analysis of atrial arrhythmias. The methods are based on adaptive filters (AdF), neural networks (NN), and the space-time of an averaged beat for subsequent removal from the ECG signal, the comparison is made with reference to the results obtained with the adaptive filtering method by Thakor. The results show that the methods based on NN and AdF are more robust to morphological changes of the signal and in the presence of noise than non-adaptive methods, also have the advantage that they do not require a pre-detection stage of QRST, however, for the average beat alignment method, best results are obtained when there are no QRS detection failures.In Spanish: En este trabajo se compara el rendimiento- de tres t{\'e}cnicas de cancelaci{\'o}n de QRS con el fin de obtener un ECG residual que contenga solo informaci{\'o}n de la actividad auricular (AA), facilitando as{\'i} la detecci6n de la onda P del ECG y/o el an{\'a}lisis de arritmias auriculares. Los m{\'e}todos se basan en filtros adaptativos (AdF), redes neurales (NN), y en el alineamiento espacio-temporal de un latido promedio para su posterior sustracci{\'o}n de la se{\~n}al de ECG, la comparaci{\'o}n se establece tomando como referencia los resultados obtenidos con el m{\'e}todo de filtraje adaptativo de Thakor. Los resultados comprueban que los m{\'e}todos adaptativos basados en NN y FA son m{\'a}s robustos frente a los cambios morfol{\'o}gicos de la se{\~n}al y en presencia de ruido que los m{\'e}todos no adaptativos, adem{\'a}s tienen la ventaja de que no necesitan una etapa de detecci{\'o}n previa de QRST, sin embargo con el m{\'e}todo de alineaci{\'o}n del latido promedio se obtienen mejores resultados cuando no hay falla de detecci{\'o}n de QRS.",
keywords = "ECG denoising, atrial activity cancelation, atrial fibrilation ECG, QRS cancelation methods, arrhythmias, averaged QRS complex.",
author = "MA Diaz and AI Hernandez and F Mora and OJ Escalona",
year = "2000",
month = "9",
day = "1",
language = "English",
isbn = "980-329-286-2",
pages = "98--103",
booktitle = "Tendencias Actuales en Bioingenieria",

}

Diaz, MA, Hernandez, AI, Mora, F & Escalona, OJ 2000, Comparación de técnicas de cancelación de la actividad auricular en el ECG. in Tendencias Actuales en Bioingenieria. Caracas, Venezuela, pp. 98-103.

Comparación de técnicas de cancelación de la actividad auricular en el ECG. / Diaz, MA; Hernandez, AI; Mora, F; Escalona, OJ.

Tendencias Actuales en Bioingenieria. Caracas, Venezuela, 2000. p. 98-103.

Research output: Chapter in Book/Report/Conference proceedingChapter

TY - CHAP

T1 - Comparación de técnicas de cancelación de la actividad auricular en el ECG

AU - Diaz, MA

AU - Hernandez, AI

AU - Mora, F

AU - Escalona, OJ

PY - 2000/9/1

Y1 - 2000/9/1

N2 - In English: In this paper, the performance-three QRS cancellation techniques compared to obtain a residual ECG information containing only atrial activity (AA), thereby facilitating detection of the P wave in the ECG and/or analysis of atrial arrhythmias. The methods are based on adaptive filters (AdF), neural networks (NN), and the space-time of an averaged beat for subsequent removal from the ECG signal, the comparison is made with reference to the results obtained with the adaptive filtering method by Thakor. The results show that the methods based on NN and AdF are more robust to morphological changes of the signal and in the presence of noise than non-adaptive methods, also have the advantage that they do not require a pre-detection stage of QRST, however, for the average beat alignment method, best results are obtained when there are no QRS detection failures.In Spanish: En este trabajo se compara el rendimiento- de tres técnicas de cancelación de QRS con el fin de obtener un ECG residual que contenga solo información de la actividad auricular (AA), facilitando así la detecci6n de la onda P del ECG y/o el análisis de arritmias auriculares. Los métodos se basan en filtros adaptativos (AdF), redes neurales (NN), y en el alineamiento espacio-temporal de un latido promedio para su posterior sustracción de la señal de ECG, la comparación se establece tomando como referencia los resultados obtenidos con el método de filtraje adaptativo de Thakor. Los resultados comprueban que los métodos adaptativos basados en NN y FA son más robustos frente a los cambios morfológicos de la señal y en presencia de ruido que los métodos no adaptativos, además tienen la ventaja de que no necesitan una etapa de detección previa de QRST, sin embargo con el método de alineación del latido promedio se obtienen mejores resultados cuando no hay falla de detección de QRS.

AB - In English: In this paper, the performance-three QRS cancellation techniques compared to obtain a residual ECG information containing only atrial activity (AA), thereby facilitating detection of the P wave in the ECG and/or analysis of atrial arrhythmias. The methods are based on adaptive filters (AdF), neural networks (NN), and the space-time of an averaged beat for subsequent removal from the ECG signal, the comparison is made with reference to the results obtained with the adaptive filtering method by Thakor. The results show that the methods based on NN and AdF are more robust to morphological changes of the signal and in the presence of noise than non-adaptive methods, also have the advantage that they do not require a pre-detection stage of QRST, however, for the average beat alignment method, best results are obtained when there are no QRS detection failures.In Spanish: En este trabajo se compara el rendimiento- de tres técnicas de cancelación de QRS con el fin de obtener un ECG residual que contenga solo información de la actividad auricular (AA), facilitando así la detecci6n de la onda P del ECG y/o el análisis de arritmias auriculares. Los métodos se basan en filtros adaptativos (AdF), redes neurales (NN), y en el alineamiento espacio-temporal de un latido promedio para su posterior sustracción de la señal de ECG, la comparación se establece tomando como referencia los resultados obtenidos con el método de filtraje adaptativo de Thakor. Los resultados comprueban que los métodos adaptativos basados en NN y FA son más robustos frente a los cambios morfológicos de la señal y en presencia de ruido que los métodos no adaptativos, además tienen la ventaja de que no necesitan una etapa de detección previa de QRST, sin embargo con el método de alineación del latido promedio se obtienen mejores resultados cuando no hay falla de detección de QRS.

KW - ECG denoising

KW - atrial activity cancelation

KW - atrial fibrilation ECG

KW - QRS cancelation methods

KW - arrhythmias

KW - averaged QRS complex.

M3 - Chapter

SN - 980-329-286-2

SP - 98

EP - 103

BT - Tendencias Actuales en Bioingenieria

CY - Caracas, Venezuela

ER -

Diaz MA, Hernandez AI, Mora F, Escalona OJ. Comparación de técnicas de cancelación de la actividad auricular en el ECG. In Tendencias Actuales en Bioingenieria. Caracas, Venezuela. 2000. p. 98-103