Exercise training comprising of single 20-s cycle sprints does not provide a sufficient stimulus for improving maximal aerobic capacity in sedentary individuals

P Songsorn, A Lambeth-Mansell, Jacqueline L. Mair, M Haggett, Ben Fitzpatrick, J Ruffino, A Holliday, Richard Metcalfe, NBJ Vollaard

Research output: Contribution to journalArticlepeer-review

13 Citations (Scopus)
34 Downloads (Pure)

Abstract

Purpose
Sprint interval training (SIT) provides a potent stimulus for improving maximal aerobic capacity (V˙O2max), which is among the strongest markers for future cardiovascular health and premature mortality. Cycling-based SIT protocols involving six or more ‘all-out’ 30-s Wingate sprints per training session improve V˙O2max, but we have recently demonstrated that similar improvements in V˙O2max can be achieved with as few as two 20-s sprints. This suggests that the volume of sprint exercise has limited influence on subsequent training adaptations. Therefore, the aim of the present study was to examine whether a single 20-s cycle sprint per training session can provide a sufficient stimulus for improving V˙O2max.

Methods
Thirty sedentary or recreationally active participants (10 men/20 women; mean ± SD age: 24 ± 6 years, BMI: 22.6 ± 4.0 kg m−2, V˙O2max: 33 ± 7 mL kg−1 min−1) were randomised to a training group or a no-intervention control group. Training involved three exercise sessions per week for 4 weeks, consisting of a single 20-s Wingate sprint (no warm-up or cool-down). V˙O2max was determined prior to training and 3 days following the final training session.

Results
Mean V˙O2max did not significantly change in the training group (2.15 ± 0.62 vs. 2.22 ± 0.64 L min−1) or the control group (2.07 ± 0.69 vs. 2.08 ± 0.68 L min−1; effect of time: P = 0.17; group × time interaction effect: P = 0.26).

Conclusion
Although we have previously demonstrated that regularly performing two repeated 20-s ‘all-out’ cycle sprints provides a sufficient training stimulus for a robust increase in V˙O2max, our present study suggests that this is not the case when training sessions are limited to a single sprint.
Original languageEnglish
Pages (from-to)1511-1517
Number of pages7
JournalEuropean Journal of Applied Physiology
Volume116
Issue number8
DOIs
Publication statusPublished (in print/issue) - 6 Jun 2016

Keywords

  • VO2max
  • High-intensity interval training
  • SIT
  • Wingate sprint
  • Sprint interval

Fingerprint

Dive into the research topics of 'Exercise training comprising of single 20-s cycle sprints does not provide a sufficient stimulus for improving maximal aerobic capacity in sedentary individuals'. Together they form a unique fingerprint.

Cite this