Abstract
This research aims to conduct a pilot study for the in-fire performance of headed studs, commonly used in composite structures over the world. The robustness of the shear studs in fire appears to be a key element to govern the composite behaviour after a sudden local instability developed in structures such as trusses and cellular beams. In order to experimentally evaluate the residual strength of studs in fire, the standard push-out test was modified for a half of the original set-up to be equipped with a furnace. The adjustments allow the steel section to have a 3-sided exposure against fire. Under the Standard ISO fire, the modified push-out tests under loading were conducted to identify the failure mechanism of the studs in relation to temperature developments.
| Translated title of the contribution | Study on Fire Performance of Stud Connectors |
|---|---|
| Original language | Korean |
| Pages (from-to) | 59-66 |
| Number of pages | 8 |
| Journal | Journal of Korean Institute of Fire Science and Engineering |
| Volume | 23 |
| Issue number | 4 |
| Publication status | Published (in print/issue) - Aug 2009 |
Keywords
- Fire performance
- Stud connectors
- Composite beam
- Push - out test
Fingerprint
Dive into the research topics of 'Study on Fire Performance of Stud Connectors'. Together they form a unique fingerprint.Cite this